06/29/98 Current Production Release SX00064-A06 5215 CB Download Image REASON FOR CHANGE(S) : Symptom : Interrupt level test in the CB diagnostics always reports a timeout. Major test 3, Minor test 7. Cause : The address for the interrupt service routine for the test was not being loaded, leaving the default routine in the table which was not setting the flag being monitored by the diagnostic code. Solution: Install the appropriate vector when running the test and restore the default after the test. ----------------------------------------------------------------------------- Symptom : CB DMA diagnostic runs forever when selecting SRAM as the source. Major test 3, Minor test 5 and 6. Cause : The implementation of an extra options field for the READ/WRITE buffer commands used the wrong options word when determining whether the loop enable bit was set or not. The loop bit and the SRAM select bit are the same, just in different option fields. Solution: Correct the code to use the correct options field when determining loop enable. INTERPHASE (i) CORPORATION HOTLINE:+1-214-654-5555 13800 Senlac * Dallas,TX 75234-8823 intouch@iphase.com +1-214-654-5000 FAX:+1-214-654-5500 http://www.iphase.com